What are the ways to adjust the electric gate valve

更新時間:2018.07.20
1. Torque limitation mechanism adjustment
Electric gate valves are used in different places due to the difference in water pressure or air pressure between the two ends of the gate (when the gate valve is closed), torque limiting mechanism can be appropriately adjusted. When used in places with low water pressure or air pressure difference at both ends of the electric gate valve gate, the torque limiting mechanism should be adjusted to a lower torque. When using the HZ series, z series or ZB series with mushroom reed and its lapped HZ series torque limiting mechanism, the adjusted torque value is required to be larger, and vice versa. The above series of adjustments are the same. When adjusting the ZD series valve electric device, remove the side cover of the box body, adjust torque limiting mechanism, loosen the tightening screw in the adjusting nut, loosen the adjusting nut, loosen the button torque spring, and put it in the most loose position. Then, tighten the tightening screw in the adjusting nut and fix the adjusting nut. Note that the top of the tightening screw must be placed in the shaft slot. If the top does not align exactly with the shaft slot, just turn the adjusting nut slightly in the direction of the compression spring and make it align with the shaft slot.
Then install the side cover and adjust the open valve. If the torque limiting mechanism ACTS, the spring is too loose to tighten until it does not act. In this way, the torque limiting mechanism can work under low torque, so as to ensure that when the electric gate valve fails due to the failure of the travel control mechanism, when the electric gate valve or other reasons overtorque, the torque limiting mechanism can operate reliably, and the motor power can be cut off to protect the valve from damage. Electric gate valves used in some places do not have to be adjusted to close too tightly, so it is better to adjust the position to a semi-circle (or one lap) after manually closing. When the electric gate valve is installed in a place with a large water pressure difference (or pressure difference), the torque limit mechanism should be adjusted to the appropriate opening and closing torque. If the outlet water gate valve installed in the water pump room is installed, after the start of the water pump, the outlet water pressure is greater when the gate valve is not opened. At this time, the larger the 121 diameter of the outlet gate valve is, the greater the torque used to open the gate valve is. In particular, when there is no pressure in the pipe, the one-way pressure on the gate plate of the gate valve is the maximum. At this time, the adjusting nut compression spring is adjusted to normally open and close the gate valve, and the torque limiting mechanism does not operate.
The electric gate valve used in the water pump room must be adjusted to the fully open and fully closed position, otherwise it is easy to damage the sealing cover of the gate valve and cause water leakage. Because the electric gate valve installed in this place is close to the water outlet of the pump, the water flow rate is high and unstable. At this time, if the gate valve is not fully opened, part of the gate plate will move forward and backward due to the impact of water flow, which will wear the sealing cover of the gate, and the water leakage will affect the service life of the valve. In addition, electric gate valve should be avoided to adjust the flow, otherwise it is easy to damage the sealing surface of gate valve. In addition, the technology of frequency conversion speed regulation is developing rapidly in recent years. The water pump flow regulation should adopt frequency conversion speed regulation technology to save energy and improve the working efficiency of water pump.
2. "open and close" position adjustment of electric gate valve
Adjust the opening and closing of the electric gate valve. According to the adjustment requirements of each manufacturer, the valve should be closed manually to the "all closed" or "all open" position. If it takes more time to manually close and open large-caliber gate valves as required, it will be difficult. A new adjustment method is introduced: if you know the stem tooth distance of the valve, it is easy to adjust the electric gate valve. The valve diameter produced in China is dn400-dn600, and the valve stem tooth distance is generally 8ram. The tooth spacing of valve stem of DN600 and above is generally 10ram. If possible, ask the manufacturer of gate valves for stem pitch. When adjusting the valve actuator, if you know the position of the gate valve in advance, and if you know that the gate valve is in the fully closed position, adjust the "fully closed" position first. First, manually turn the gate valve in the open direction, such as half or one turn on the stem.
Then send the power to press the "on" button. Check the steering. If the steering of the stem is consistent with that of the stem when the valve is manually opened after pressing the open valve button, it indicates that the phase sequence of the motor is consistent with the direction of the valve's electrical controller. At this point, the stroke control mechanism of the gate valve can be adjusted to the full closed position. After the full closed position is adjusted, the full open position of the gate valve can be adjusted. At this point, when opening the gate valve, count the number of the number of turns on the stem of the gate valve to know whether the "full open" position. If it is an electric gate valve of DN500, its stem tooth distance is 8ram, and the stem turns once to open 8ram. When fully open, the gate valve plate shall move up 500ram, so the stem shall rotate 500/8 =62 when fully open. Five laps. At this point, press the open valve button to 63 circles and the valve will reach the "all open" position, adjust the stroke controller of the valve electric device, and make the "all open" position of the micro-switch action can be. After that, the electric gate valve can be closed, opened for inspection, and the adjustment ends. If the electric gate valve is in the open position before adjustment, the open position should be adjusted first, as described above.
The article comes from: http://www.yxhj800.cn

今天是
HOME ABOUT US NEWS PRODUCTS NETWORK ORDER <CONTACT US 中文

Copyright 2013 Bohai Valve Co., Ltd. Yongjia LUOTUO All Right Reserved. Address: Yongjia County, Wenzhou City, Zhejiang Province town of North ICP No.: ICP 12045727 No. -1

主站蜘蛛池模板: 久久久久亚洲精品无码网址色欲 | 黑粗硬大欧美视频 | 娇妻在厨房被朋友玩得呻吟 | 欧美一区二区三区在线视频播放 | 播放一区二区 | 日本视频中文字幕一区二区三区 | 91精品国产乱码久久久久久张柏芝 | 日韩成人免费观看 | 久久久女人与动物群交毛片 | 浪潮AV激情高潮国产精品 | 欧洲人与动牲交α欧美精品 | 国产美女被遭强高潮露开双腿 | 亚洲AV无码一区二区三区天堂网 | 日韩国产成人精品影院 | 操比免费视频 | 91在线综合 | 国产精品乱码一区二区三区视频 | 欧美成人精品一区二区 | 少妇被粗大的猛烈进出96影院 | 久久久国产成人 | 亚洲欧美一区二区三区情侣bbw | 天天操天天碰 | 欧美黄色三级视频 | 国产综合经典三级 | 五十路熟女一区二区三区 | 97久久人妻一区二区中文无码 | 人人妻人人藻人人爽欧美一区 | 日韩一级色片 | 日韩一区二区三免费高清在线观看 | 18禁黄污无遮挡无码网站 | 中字幕久久久人妻熟女天美传媒 | 亚洲无码av一区2区三区四区 | 黄色免费观看网址 | 无码无遮挡又大又爽又黄的视频 | 320lu小视频官网自拍首页视频 | 男人日b视频 | 黑人巨大精品一区二区 | 麻豆精品久久久久久久综合 | 天堂中文在线观看 | 中文字幕肉感巨大的乳专区 | 日本一道综合久久aⅴ免费 中文在线视频 |